England's Stove Works 27-C2000 Manuel du propriétaire

Naviguer en ligne ou télécharger Manuel du propriétaire pour Poêles England's Stove Works 27-C2000. England's Stove Works 27-C2000 Owner's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INSTALLATION AND OPERATION MANUAL
Thank you for purchasing this product, which is from a fine line of heating equipment.
We wish you many years of safe heating pleasure with your new coal stove.
NOTE: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT
RETURN IT TO THE DEALER.
CONTACT CUSTOMER SERVICE @ 1-800-245-6489.
Visit our web page at www.englandsstoveworks.com for helpful information,
frequently asked questions, parts and accessory orders and more.
CAUTIONS AND WARNINGS:
CAUTION: Do not install this unit in a mobile home. This unit must be installed
in accordance with the instructions and comply with your local
building and fire codes. Follow the pipe manufacturer’s instructions
for passing through combustible walls and ceilings
.
WARNING: READ THIS ENTIRE MANUAL PRIOR TO INSTALLATION AND SAVE IT
FOR FUTURE USE. KEEP CHILDREN AND ALL COMBUSTIBLE
MATERIALS AWAY FROM THIS STOVE.
MODEL NUMBERS: 27- C3000, 50-SHWC3 & 50-TRWC3
27- C2000, 50-SHWC2 & 50-TRWC2
Note: Maintain a minimum of thirty inches (30”) from the firebox and
eighteen inches (18”) from the flue pipe to a combustible surface.
SAFETY NOTICE
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN
PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. FOR YOUR
SAFETY AND PROTECTION, FOLLOW ALL THE INSTRUCTIONS. CONTACT
YOUR LOCAL BUILDING OR FIRE OFFICIALS FOR RESTRICTIONS AND
INSTALLATION INSPECTIONS IN YOUR AREA.
Rev. 1/06
England’s Stove Works highly recommends the use of smoke detectors and Carbon
Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s
instructions when using smoke and Carbon Monoxide detectors.
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - →SAFETY NOTICE←

INSTALLATION AND OPERATION MANUAL Thank you for purchasing this product, which is from a fine line of heating equipment. We wish you many years of s

Page 2

Retain for your files: Model Number __________________________ Date of Purchase ________________________ Date of Manufacture _________________ Seri

Page 3 - SECTION I: FLUE SYSTEM

WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________

Page 4

A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works wa

Page 5

SECTION I: FLUE SYSTEM A. Existing Flue System This unit is designed to connect to an existing flue system, such as masonry or a pre-manufactur

Page 6

We also recommend (for easy access and clean out) that you have a flue door located at least two feet (2’) below your flue thimble connect

Page 7

B. Wall Protection This stove can be placed within thirty inches (30”) of a combustible wall such as paneling and wallboard. The local code in

Page 8

SECTION IV: OPERATING INSTRUCTIONS A. Building a Fire Type of fuel for USA – Coal only (Wood can be used to start the fire). Type of fuel for CANA

Page 9

damage; therefore do not use the stove until the flue system is inspected and, if necessary, repaired or replaced. A chimney sweep can perform this in

Page 10

B. Firebrick The coal stove is equipped with high density, high temperature firebrick. If any of the brick becomes chipped or cracked, especiall

Page 11 - IMPORTANT NOTICE

It is very important that the installation be made airtight. This is best accomplished by using stove cement at each pipe joint, where the first

Commentaires sur ces manuels

Pas de commentaire